B6 Series 

Blaze B605

Freestanding contemporary looking with amazing coverage and efficiency. 3 speed remote control fan. 6mm firebox and large ceramic glass/steel door

87%

0.67

Emissions

Peak

g/kg

sq mt

Coverage

150-190

Efficiency

1000mm wide hearth (minimum)
Coffee Table base with toughened glass top.
Firebrick internal lining
3 speed remote control fan.
6mm steel construction
B605 Weight 153kg

Blaze B605 Dimensions 

Blaze B605 Clearances

Corner Installation
with 900mm Rear Flue Shield : C = 150mm | F = 300mm

with Decromesh :                    C = 150mm | F = 300mm

The 490 mm half round stainless steel inner reflector supplied with heater must be fitted inside the Decromesh.

Click for more information on
B605 Standard Installation Clearances  

Standard Installation
 

with 900mm Rear Flue Shield : F = 300mm | R = 150mm

SC = 425mm | SR = 505mm | SL = 425mm

 

with Decromesh : F = 300mm | R = 225mm

SC = 425mm | SR = 505mm | SL= 425mm

The 490 mm half round stainless steel inner reflector supplied with heater must be fitted inside the Decromesh.

Blaze B605 Hearth

Unless the heater will be standing on a heat resistant floor such as concrete slab with slate or tiles, it will be necessary to provide a floor protector (hearth). The dimensions given above are the minimum required for the floor protector to extend beyond the firebox door opening. It must extend no less than 300mm in front of the door opening, no less than 200mm either side of the door opening, and extend under the heater. It may be desirable, for example aesthetic reasons, for the floor protector to be larger than these minimum dimensions. The floor protector can be constructed of either: -
a) toughened glass no less than 10mm thick, OR
b) non-combustible material no less than 7.5mm thick and with a thermal conductivity not greater than 0.33W/m ⁰K, e.g. compressed cement sheet. The floor protector may be laid directly on the combustible floor. For more details and variations on floor protectors refer to AS/NZS 2918:2001 Clause 2.2, 3.3.1, & 3.3.2.

Please note, that 1000mm wide hearth dimensions are the minimum and may need to be extended to reach the wall behind the heater.

Overall average efficiency burning hardwood is 70% as tested by
Adelaide Heating Technology
B605 DOWNLOADS

Installation

Operating

Brochure