B1 Series 

Blaze B100

Freestanding small in footprint but powerful radiant heater with simple to use features. Cast iron door with 6mm steel construction, looks great in either a man cave or any living space.

900mm wide hearth (minimum)
B100 Weight 115kg
6mm steel construction
Ceramic glass, with top air-slide and stainless steel handle.
Firebrick internal lining
Approved wood storage box.

Blaze B100 Dimensions 

Blaze B100 Clearances

Corner Installation
with 900mm Rear Flue Shield : C = 400mm | F = 300mm
with Decromesh :                    C = 400mm | F = 300mm
The 490 mm half round stainless steel inner reflector supplied with heater must be fitted inside the Decromesh.
Standard Installation
with 900mm Rear Flue Shield : S = 700mm | R = 200mm | F = 300mm
with Decromesh :                    S = 600mm | R = 225mm | F = 300mm
The 490 mm half round stainless steel inner reflector supplied with heater must be fitted inside the Decromesh.

Blaze B100 Hearth

Unless the heater will be standing on a heat resistant floor such as concrete slab with slate or tiles, it will be necessary to provide a floor protector (hearth). The dimensions given above are the minimum required for the floor protector to extend beyond the firebox door opening. It must extend no less than 300 mm in front of the door opening, no less than 200mm either side of the door opening, and extend under the heater. It may be desirable, for example aesthetic reasons, for the floor protector to be larger than these minimum dimensions. The floor protector can be constructed of either: -
a) toughened glass no less than 10mm thick, OR
b) non-combustible material no less than 7.5mm thick and with a thermal conductivity not greater than 0.33W/m ⁰K, e.g. compressed cement sheet. The floor protector may be laid directly on the combustible floor. For more details and variations on floor protectors refer to AS/NZS 2918:2001 Clause 2.2, 3.3.1, & 3.3.2.
Please note, that 900mm wide hearth dimensions are the minimum and may need to be extended to reach the wall behind the heater.

Installation

Operating

Brochure

Overall average efficiency burning hardwood is 75% as tested by
Adelaide Heating Technology
B100 DOWNLOADS